Scientific Lasers

Laser shock peening, LiDAR, Spectroscopy, PIV, LIBS

Products

LAMBER-C Series high energy pulsed laser

Features:

● 2-6J@1064nm, harmonics from 532 to 266nm
● 1-10Hz / 8-10ns
● Output near flat top beam
● Compact and rugged industrial laser head design
● Injection seeded single longitudinal mode (SLM) option
● Output Faraday rotation isolator option


Applications:

● Laser shock peening
● Pumping for TW/PW system
● Material damage threshold research
● Large area ablation
● Plasma physics
● Dye laser pumping
● Wafer annealing


LAMBER-C Series high energy pulsed laser

  • Product Size Diagram

  • Specification Parameter

  • PDF Online Preview

  • LAMBER-C02.png

  • Beam characteristics






    Version

    LAMBER-C02

    LAMBER-C03

    LAMBER-C04

    LAMBER-C06

    Repetition Rate1(Hz)

    1-10Hz

    Energy(mJ)


    1064nm

    2000

    3000

    4000

    6000

    532nm

    1000

    1500

    2000

    3000

    355nm

    600

    900

    1100

    1700

    266nm

    200

    250

    350

    520

    Energy Stability RMS(%)


    1064nm

    0.7%

    532nm

    1.2%

    355nm

    2.5%

    266nm

    3.5%

    Pulsewidth FWHM2(ns)

    7-10ns

    Divergence3(mrad)

    <0.5mrad, (<3mrad for Multimode)

    Pointing Stability4(μrad)

    <20μrad

    Timing Jitter RMS 5(ns)

    <0.5ns

    Beam Diameter(mm)

    ~11

    ~13

    ~15

    ~18

    Beam Spatial Profile

    Top hat

    Near Field Fit to Gaussian<1m

    70%

    Far Field Fit to Gaussian(∞)

    95%

    Beam Circularity(%)>95%

    Polarization

    Linear

    Linewidth(cm-1


    Standard

    1

    Injection seeded SLM6

    0.005

    General characteristics


    Flashlamp life time>50 million shots

    AC Input

    220 VAC ±5%  50-60Hz

    Power Consumption

    <3kW(2J at10Hz)

    Operating Conditions

    Temperature 5-35℃  Humidity<60%

    NOTES

    1.All specifications at 1064nm and maximum repetition rate unless otherwise noted.

    2.Full width at half maximum.

    3.Full angle for 86.5% of energy.

    4.Maximum deviation from beam mean centroid.

    5.With respect to external trigger.